rotorloop

Product tour

What your team sees.

These are the screens in the current build of Rotorloop, redrawn here with a simulated school. The dial on this page works: drag it or use the arrow keys.

01 — Rooms

Every room, colored by how far it is from its target.

The first screen lists rooms by the names your staff use, not controller names. Each row says what the unit is doing and how warm or cool the room is.

  • Seven shades from very cold to very hot, with "Comfortable" in white.
  • Open a room to see the dial. Drag the ring, or tap − and +, then choose how long.
  • Held until 4:30 PM tells everyone the room is on a temporary change and when it ends.
rotorloopExample school (simulated)Online

9 rooms · 1 too warm · 1 too cool

1st Floor SouthRTU 15 · Fan only · target 70°Comfortable70.1°
Dining RoomRTU 20 · Idle · target 70°A bit cool68.8°
GymRTU 11 · Heating, stage 2Held until 4:30 PM64.8°
KitchenRTU 10 · Cooling, stage 2Too warm75.2°
ShulRTU 17A · Cooling, stage 1A bit warm72.4°

Shul

RTU 17A · Cooling, stage 1

Drag the ring

Keep it for 2 hours · until 2:15 PM

Set 70° until 2:15 PM
02 — Equipment

Every machine, with the controls you're allowed to use.

The Equipment tab lists every device the Connector found: rooftop units, boilers, meters, fans. Each shows OK, its faults or alarms, or Offline.

  • Numbers get − / + and a typed value. On/off and modes get one button each.
  • Every control shows its allowed range and, while held, when the change ends.
  • Back to automatic now hands control straight back to the equipment's own logic.
rotorloopExample school (simulated)Online

13 devices · 2 need attention · 1 with changes held

Boiler 1Boiler room · 5 points, 2 adjustable1 heldOK
Exhaust fan EF-3Kitchen roof · 3 pointsOffline
Main power meterElectrical room · 4 pointsOK
RTU 10Kitchen · 9 points, 3 adjustable1 fault

Boiler 1

Boiler room

Supply water setpoint
Now 146° · allowed 120 to 180 °F
Held until 10:18 AM
−146+Back to automatic now
Enable
Now On
OnOff
All readings
PointValueAccess
Supply water temp138.2°Read only
Return water temp121.4°Read only
Burner onOnRead only
03 — Point settings

You decide what can change, and how far.

Admins see every point the site reports. Everything starts read-only. Allowing a change is a deliberate, per-point decision.

  • Set the lowest and highest values anyone may set, and the longest hold.
  • Readings and status points show Reading only: there's nothing to change.
  • Life-safety points are locked. So are points the equipment couldn't take back.
  • Settings reach the site in about a second and stay enforced there if the internet drops.
rotorloopExample school (simulated)Online
PointNowAllow changesLowestHighestLongest hold (min)
Shul · RTU 17A
ZN-T-SP
setpoint
70 °F6676240
SF-C
command
On——120
OCC-MODE
setpoint
Occupied——
SMOKE-DET
Life safety
Normal———
ZN-T
reading
72.4 °FReading only
04 — People and keys

Four roles, and rules the server enforces.

  • Viewer sees everything, changes nothing.
  • Operator makes changes within the limits.
  • Admin manages operators, viewers and point settings.
  • Owner can do everything, including adding admins.

Nobody can change their own role. There's always at least one owner. Access keys are shown once and can be revoked at any time.

rotorloopExample school (simulated)Online
PersonRoleStatusKeysLast active
Facilities lead (you)OwnerActive1Now
Business officeAdminActive1Yesterday
Day custodianOperator ▾Active29:42 AM
HVAC contractorViewer ▾Disabled0Oct 28
05 — Activity

Every change, including the ones that were refused.

The activity log records who asked for what, the value, and what happened: done, blocked, or refused by the equipment. It can be searched and filtered by outcome.

Each room also shows its own recent activity, so the next person can see why it's at 66°.

rotorloopExample school (simulated)Online
  • Connector: Returned Gym to scheduleDone
  • Day custodian: Tried to change Kitchen (ZN-T-SP) to 62out of range
  • Facilities lead: Changed Gym (ZN-T-SP) to 66Done
  • Business office: Allowed changes to Shul (ZN-T-SP), 66–76Done
  • Site connector connectedDone
06 — Not there yet

What the current build doesn't do.

  • History and trend charts. Rotorloop shows live values. Charts over days and weeks are next.
  • Schedules. Weekly schedules still live in your controllers. Rotorloop's holds sit on top of them.
  • Alerts. Faults and offline devices show in the app, but nothing emails or texts you yet.
  • Single sign-on. Sign-in uses access keys today. Google and Microsoft sign-in are planned.
  • Live buildings. The BACnet and Modbus drivers have been tested against simulated devices, not yet on a live site.

See what changed in each version →

Want to see it on your own equipment?

Early sites get set up with us, Connector included.